🔌

Current Converter

✓ Free & no signup 🔒 Runs 100% in your browser Updated 2026-11-25 Unit Converter Tools
—
Microamperes
—
Milliamperes
—
Amperes
—
Kiloamperes

Electric current is the flow of charge through a circuit, and it spans an enormous numeric range: a sleeping microcontroller draws a few microamps, an LED needs about 20 milliamps, a phone charging over USB pulls 2 amps, and an industrial welder or a lightning bolt reaches thousands of amps. This converter handles the four everyday units — microamps (µA), milliamps (mA), amps (A), and kiloamps (kA) — in one step. Enter a value, pick its unit, and all four conversions appear at once, updating live as you type.

Everything runs locally in your browser. There is no upload, no account, and no cost: the numbers recalculate on each keystroke, and the page behaves the same on a phone at the workbench as it does on a desktop.

The simultaneous display is the point. A sensor datasheet might quote standby current in µA, your multimeter reads in mA, and your power-budget spreadsheet is in A. Entering the value once and seeing 4,500 µA, 4.5 mA, and 0.0045 A side by side removes the most common source of order-of-magnitude mistakes in electronics work.

What Units Does This Converter Handle?

The four units cover practically the whole range of currents you will meet in circuits, devices, and power systems:

  • Microamps (µA). One millionth of an amp. Sleep-mode current in microcontrollers, sensor bias currents, leakage through capacitors, and watch-battery loads all live here. A typical MCU in deep sleep draws 1–10 µA.
  • Milliamps (mA). One thousandth of an amp. LED drive currents, small circuit loads, analog sensor signals, and the classic 4–20 mA industrial control loop all sit in this range.
  • Amps (A). The SI base unit of current. Phone chargers, laptop supplies, household appliances, and automotive loads are specified in amps.
  • Kiloamps (kA). One thousand amps. Industrial welding, busbar ratings, switchgear fault-current ratings, and lightning discharges reach this scale.

The scaling is pure decimal: 1 A = 1,000 mA = 1,000,000 µA, and 1 kA = 1,000 A. The ampere itself is an SI base unit; since 2019 its definition is tied to the elementary charge, so one amp corresponds to a flow of roughly 6.24 × 10^18 elementary charges per second.

How to Use This Converter (Step by Step)

  1. Type the current value you have. Decimals and large numbers both work — 0.00045, 20, 2000, 65000.
  2. Select the unit the value is currently in: µA, mA, A, or kA.
  3. Read all four results. They refresh on every keystroke; there is no convert button to press.
  4. Change the value or the selected unit to start a new conversion.

Worked example one: enter 20 and choose mA — the standard drive current for an indicator LED. The results are 20,000 µA, 0.02 A, and 0.00002 kA. Worked example two: enter 2 and choose A — a typical phone charge rate. The results are 2,000,000 µA, 2,000 mA, and 0.002 kA. Both take about three seconds, and neither involves a search or a formula lookup.

How It Works: The Conversion Factors

The tool is built on three exact decimal factors:

  • 1 mA = 1,000 µA
  • 1 A = 1,000 mA = 1,000,000 µA
  • 1 kA = 1,000 A = 1,000,000 mA

Internally, your input is converted to a base value in amps and the other three results are derived from that single base, so the whole set stays mutually consistent. There is no rounding chain: the µA figure you see is computed from the same source value as the kA figure next to it.

Two worked examples worth memorizing: a 5 µA sleep current is 0.005 mA and 0.000005 A — five millionths of an amp, which is why it barely dents a 2,000 mAh battery. And a 300 A welding current is 300,000 mA and 0.3 kA. Notice the µA and A figures differ by a factor of a million; that gap is exactly where unit confusion bites.

Reference Table: One Unit Expressed in All Four

FromµAmAAkA
1 µA10.0010.0000010.000000001
1 mA1,00010.0010.000001
1 A1,000,0001,00010.001
1 kA1,000,000,0001,000,0001,0001

A few real-world anchors make the table concrete: a human can just feel about 1 mA; a household GFCI trips around 5–6 mA of leakage; an LED indicator runs at 20 mA; a phone fast-charges at 2–3 A; a car starter motor pulls 150–200 A; and a large lightning stroke carries 20–30 kA.

Common Use Cases

  • LED resistor calculations. An indicator LED rated 20 mA on a 5 V supply with a 2 V drop across the resistor needs R = (5 − 2) / 0.02 = 150 Ω. Converting 20 mA to 0.02 A first is the step people get wrong; this tool makes the value impossible to misread.
  • Battery-life estimates. Divide battery capacity by draw: a 2,500 mAh cell feeding a 4.5 mA sensor lasts roughly 2,500 / 4.5 ≈ 555 hours, about 23 days. If the datasheet quotes 4,500 µA, the conversion must be right or the estimate is off by 1,000×.
  • Charger and power-supply checks. A 2 A phone charger at 5 V delivers 10 W; a laptop supply at 3.25 A and 20 V delivers 65 W. Converting to a common unit keeps wattage math clean.
  • Industrial and automotive work. Welding settings in the hundreds of amps, breaker fault ratings like 10 kA, and starter-motor draws all cross unit boundaries; entering the number once shows every scale.
  • Homework and study. Physics and electronics courses constantly mix µA, mA, and A in the same problem set; the tool is a fast way to check your own arithmetic.

Tips and Best Practices

  • Match the datasheet's unit exactly. Reading "4500" from a µA specification and entering it as mA turns a 4.5 mA load into 4.5 A — a thousandfold error that can destroy a component or, more often, waste an afternoon of debugging.
  • Use meters as anchors when sanity-checking. If a computed LED current comes out as 2,000 µA when you expected 20,000, the selected unit is the first thing to re-check, not the formula.
  • Do not confuse current with capacity. Milliamps (mA) describe flow rate; milliamp-hours (mAh) describe stored charge. A 2,000 mAh battery is not "2000 mA" — it can supply 2,000 mA for roughly one hour, or 200 mA for about ten.
  • Remember AC ratings are usually RMS. A "10 A" mains rating means 10 A RMS, not peak; the peak of a sinusoid is about 1.414 × the RMS value. The converter works on magnitudes and does not distinguish RMS from peak.
  • Watch the six-orders-of-magnitude jump. µA to A spans 10^6. If a result looks absurd — a phone charger showing millions of something — you probably entered the unit one notch off.

Limitations and Honest Caveats

This is a straight unit converter, not a measurement or analysis tool. It does not read current from hardware, distinguish AC from DC, convert between RMS and peak values, or handle charge (coulombs, mAh), power (watts), or resistance calculations — those are different dimensions entirely. It also does not apply tolerance or ripple assumptions; the numbers you get are exact mathematical conversions of what you typed. For converting a current value among µA, mA, A, and kA with no rounding games, it is complete; for anything beyond that, you need the surrounding formula and your own judgment.

Why the Subunits Exist at All

It is fair to ask why electronics uses µA and mA instead of just writing 0.000005 A. The answer is legibility: engineering quantities span nine orders of magnitude from sleep-mode silicon to lightning, and scientific notation in a shopping list of parts is unreadable. Subunits keep the digits meaningful — a sleep current quoted as "5 µA" carries two significant figures, while "0.000005 A" invites transcription errors. This converter preserves that convention: whatever unit you enter, the other three appear instantly in their native scales, so a datasheet value, a meter reading, and a spreadsheet budget can all be compared in one glance, entirely within your browser, with nothing sent anywhere.

Frequently Asked Questions

How many milliamps are in an amp?
Exactly 1,000. The prefix milli- means one thousandth, so 1 A = 1,000 mA and 1 mA = 0.001 A. To convert amps to milliamps, multiply by 1,000: a 2 A phone charger delivers 2,000 mA. To convert milliamps to amps, divide by 1,000: a 20 mA LED current is 0.02 A. The converter shows both directions at once — enter the value in either unit and the other appears immediately, along with µA and kA.
How do I convert microamps to milliamps?
Divide the microamp value by 1,000, because 1 mA = 1,000 µA. So 4,500 µA is 4.5 mA, and a 10 µA sleep current is 0.01 mA. Going the other way, multiply by 1,000: 0.25 mA is 250 µA. This conversion comes up constantly with sensor datasheets, which quote standby and measurement currents in µA while circuit calculations and meters usually work in mA. Enter the µA value in the converter and the milliamp, amp, and kiloamp equivalents all appear at once.
What current does a typical LED use?
A standard 5 mm indicator LED runs at about 20 mA, which is 0.02 A. Low-power types work fine at 2–5 mA with reduced brightness, while high-power LEDs for lighting are driven at 350 mA to 1,000 mA (0.35–1 A) and need proper heat sinking. Because an LED's forward voltage is fixed at roughly 2–3.4 V, you limit current with a series resistor: on a 5 V supply with a 2 V LED drop, R = (5 − 2) / 0.02 = 150 Ω. Always convert 20 mA to 0.02 A before plugging it into the resistor formula.
How many amps does a phone charger draw?
Standard USB charging runs at 1–2 A on a 5 V output, so a common charger delivers about 10 W. Fast-charging standards push higher: USB Power Delivery can supply up to 5 A, at voltages of 9 V, 15 V, or 20 V, giving 45 W to 100 W for laptops. Note the distinction between output current (at 5–20 V) and the current drawn from the wall (at 120 or 230 V), which is lower for the same wattage. A 2 A figure entered in the converter shows 2,000 mA and 0.002 kA immediately.
How much current is dangerous to humans?
Thresholds are surprisingly low. Around 1 mA through the body is barely perceptible; about 10 mA causes involuntary muscle contraction so you cannot let go; currents of 50–100 mA passing through the chest can trigger ventricular fibrillation and are potentially fatal. This is why household GFCI/RCD protectors trip at 5–30 mA of leakage. Voltage matters because it drives the current, but the injury is done by the amps — converting a scary-sounding milliamp figure to amps (100 mA = 0.1 A) puts the danger in perspective.
What is a kiloamp used to measure?
A kiloamp (1,000 A) covers currents too large for everyday wiring. Arc welders operate at roughly 100–400 A (0.1–0.4 kA); industrial busbars and switchgear carry thousands of amps; and electrical equipment is rated for fault conditions like 10 kA or 25 kA short-circuit current. The most dramatic example is lightning: a typical negative stroke carries about 20–30 kA, with strong strikes exceeding 100 kA. Because these values are unwieldy in amps, power engineering convention quotes them in kA — 20 kA rather than 20,000,000 mA.

Related Tools