Illuminance Converter

✓ Free & no signup 🔒 Runs 100% in your browser Updated 2026-11-25 Unit Converter Tools
—
Lux
—
Kilolux
—
Foot-candles
—
Phots
—
Nox

Lighting standards are written in lux, American fixture photometry is published in foot-candles, older European texts use the phot, and scientific photometry occasionally reaches for the nox — four units describing the same thing: how much luminous flux lands on a given surface. An office desk wants 300–500 lx, full summer daylight delivers about 100,000 lx, and a moonlit path offers barely 0.1 lx. This converter handles all five units — lux (lx), kilolux (klx), foot-candle (fc), phot (ph), and nox — in one step. Enter a value, pick its unit, and all five conversions refresh live as you type.

The tool runs locally in your browser: free, no signup, nothing uploaded, works on a phone. That suits the workflow — lighting audits, photography scouting, and grow-light planning all happen on-site, phone in hand, next to the meter.

Five simultaneous results matter because illuminance data crosses borders constantly. A US photometric report says 50 fc; the corresponding European standard says "minimum 500 lx". A museum conservation guideline says 50 lx; a heritage lighting scheme written decades ago says 0.005 ph. One entry converts the whole document's vocabulary at once.

What Is Illuminance?

Illuminance is luminous flux per unit area — how much visible light strikes each square meter or square foot of a surface. It is what a lux meter or phone light-meter app actually measures, and it is the number lighting codes regulate. The SI unit is the lux: one lumen spread evenly over one square meter (1 lx = 1 lm/m²).

Distinguish it carefully from its two neighbors. Luminous flux (lumens) is the total light a source emits in all directions; illuminance (lux) is what arrives at a particular surface. A 800-lumen bulb in a small room produces high illuminance on the desk; the same bulb in a warehouse produces almost none. And luminance (candelas per square meter) is brightness as seen by the eye from a given direction — a property of the surface, not the light landing on it. Lighting design moves between all three, but codes and measurements overwhelmingly speak in illuminance.

Why a "lux" and not watts? Because eyes are not equally sensitive to all wavelengths — peak sensitivity sits near 555 nm (green). Photometric units bake that sensitivity curve in, so lux measures light weighted for human vision. That weighting is also why a lux meter is a poor instrument for plants, whose photosynthesis action spectrum differs from the eye's.

What Units Does This Converter Handle?

  • Lux (lx). The SI unit: 1 lumen per square meter. The unit of European and international lighting standards (EN 12464 series), camera exposure guidance, and virtually all modern photometry.
  • Kilolux (klx). One thousand lux. Used for high illuminance: daylight scenes, surgical fields, industrial inspection, and photobiology experiments.
  • Foot-candle (fc). One lumen per square foot. The North American unit: IES (Illuminating Engineering Society) recommendations, US building codes, and fixture photometric reports. 1 fc = 10.7639 lx exactly (since 1 m² = 10.7639 sq ft).
  • Phot (ph). 1 lumen per square centimeter, so 1 ph = 10,000 lx. A legacy CGS unit found in older European and scientific literature; a 0.005 ph museum limit is the same 50 lx still cited today.
  • Nox. 0.001 lx (one millilux). A niche unit for very low light — night-vision research, astronomy-adjacent work, and dark-sky studies, where illuminance sits around 0.1–1 nox.

The conversions are all exact scale relationships: 1 klx = 1,000 lx; 1 fc = 10.7639 lx; 1 ph = 10,000 lx; 1 nox = 0.001 lx. The foot-candle factor deserves a note — it is not a round decimal because it encodes the square-foot-to-square-meter ratio (0.09290304 m² per sq ft), and 1 / 0.09290304 = 10.7639.

How to Use This Converter (Step by Step)

  1. Type the illuminance value you have — 500, 0.1, 100,000, or any decimal.
  2. Select its unit: lx, klx, fc, ph, or nox.
  3. Read all five results, updated on every keystroke with no button to press.
  4. Change the value or unit for the next comparison.

Worked example one: enter 500 and choose lx, the standard target for office writing and reading tasks. The results are 0.5 klx, 46.45 fc, and 0.05 ph — meaning the same desk would be specified as "46 foot-candles" in an American photometric report. Worked example two: enter 100,000 and choose lx, full midday daylight. The results are 100 klx, 9,290 fc, 10 ph, and 100,000,000 nox — the last number explaining why nox exists only for the dim end of the scale.

How It Works: The Conversion Factors

  • 1 klx = 1,000 lx
  • 1 fc = 10.7639 lx (from 1 sq ft = 0.09290304 m²)
  • 1 ph = 10,000 lx = 10 klx
  • 1 nox = 0.001 lx

Internally, the input is normalized to a base value in lux and the other four results derive from that single base, so the set stays mutually consistent. Two worked examples worth remembering: a 50 fc classroom converts to 50 × 10.7639 = 538 lx — just above the 500 lx standard. And a 0.1 lx moonlit night is 0.00001 ph and 100 nox, which shows how each unit occupies its native range: ph for bright scenes, nox for dark ones, fc and lx for everything in between.

Reference Table: Typical Illuminance Levels in All Five Units

Scenelxklxfcphnox
Full moon, clear night0.10.00010.00930.00001100
Public corridor1000.19.290.01100,000
Office desk work5000.546.450.05500,000
Drafting / fine inspection1,000192.90.11,000,000
Surgical operating field40,000403,716440,000,000
Full midday daylight100,0001009,29010100,000,000

The table's most useful takeaway is the ratio: daylight is roughly 200 times brighter than an office, and an office is roughly 5,000 times brighter than moonlight. Cameras and pupils handle this range automatically; lighting designers, grow-light planners, and dark-sky advocates must handle it deliberately.

Common Use Cases

  • Meeting lighting standards. EN 12464 and IES guidance specify targets by task: 300 lx for corridors, 500 lx for offices and classrooms, 750+ lx for detailed work. Converting between the European (lx) and American (fc) documents is a daily occurrence for international firms.
  • Reading photometric reports. Fixture manufacturers serving both markets publish point-by-point layouts in fc for North America and lx for Europe. A 46.45 fc figure and a 500 lx figure describe the same design point.
  • Photography and cinematography. Exposure decisions and light-meter readings in lx become scene comparisons in fc; a key light at 1,000 lx is a 92.9 fc level, familiar from studio practice.
  • Grow-light and plant-science planning. Horticultural suppliers often quote lux while research literature uses klx or photosynthetic units. Converting illuminance is the first step before translating to PPFD, which is the measurement plants actually respond to.
  • Dark-sky and night-vision work. Skyglow and scene brightness under 1 lx are quoted in nox or mlux; converting a 0.05 lx reading to 50 nox connects the two literatures.

Tips and Best Practices

  • Memorize one bridge: 1 fc ≈ 10.76 lx. Then fc-to-lx is "multiply by ten, plus a bit" and lx-to-fc is "divide by ten, minus a bit". A 50 fc spec is a little over 500 lx — the two standard systems conveniently nearly coincide at task-lighting levels.
  • Do not confuse lux with lumens or with luminance. A 1,600-lumen bulb tells you the source; 300 lx tells you the desk. Candela per square meter (nits) is a third thing again. Meter apps that mix these up produce nonsense.
  • Measure at the task plane, not the ceiling. Illuminance codes apply where work happens — desktop height, not fixture height. A conversion is only meaningful if the input was measured in the right place.
  • Remember lux is eye-weighted. For plant lighting, insect studies, or sensor calibration, photometric lux systematically misrepresents usefulness; convert to radiometric units for those tasks instead.
  • Use scene anchors. Office 300–500 lx, overcast day 1,000–10,000 lx, full daylight about 100,000 lx, moonlight 0.1 lx. If a conversion lands far from its scene, the unit selector is the suspect.

Limitations and Honest Caveats

This tool converts between units of illuminance — light arriving at a surface, weighted for human vision. It does not convert luminous flux (lumens), luminance (cd/m²), luminous intensity (candela), or radiometric power (W/m²); each is a different photometric or radiometric quantity with its own geometry. It also does not model room reflectance, fixture placement, or daylight contribution — those determine what a design achieves, not what a unit means. For exact conversion among lx, klx, fc, ph, and nox, it is complete.

Five Units, One Physical Idea

The unit sprawl in illuminance mirrors the history of measurement itself: CGS science gave us the phot a century ago, English-speaking industry gave us the foot-candle, the SI system settled on lux, and specialists added kilolux and nox for the extremes of the scale that everyday units handle awkwardly. The underlying physics never changed — lumen per area, weighted by the eye's sensitivity curve — so the conversions are simple scale factors. What changes by a factor of a million between a moonlit night and midday sun is the scene, not the arithmetic. This converter keeps all five units in one view: enter any value in lx, klx, fc, ph, or nox and the rest appear instantly, computed locally in your browser, free, with nothing sent anywhere.

Frequently Asked Questions

How do you convert lux to foot-candles?
Divide lux by 10.7639, or multiply foot-candles by 10.7639 to get lux. The factor comes from geometry: 1 square meter is 10.7639 square feet. So a 500 lx office target is 500 / 10.7639 = 46.45 fc, and a 50 fc spec is 50 × 10.7639 = 538 lx. A quick mental shortcut: foot-candles are about 10% less than lux divided by ten — 300 lx is roughly 28 fc. Enter the value in the converter and you get lx, klx, fc, phot, and nox all at once, updated live as you type.
How many lux should an office have?
International and US standards converge on 300–500 lx for office work: EN 12464 specifies 500 lx for writing, reading, and data processing, while IES recommends about 300–500 fc-equivalent levels depending on task age-group adjustments. Corridors and stairs need 100–150 lx, meeting rooms 300–500 lx, and detailed drafting 750–1,000 lx. Measured at desk height, not the ceiling. A comfortable modern office often targets 300–400 lx ambient with task lamps providing local boost — full overhead uniformity at 500 lx wastes energy compared to layered lighting. Convert any standard's figure between lx and fc in one entry.
How bright is full daylight in lux?
Direct midday sunlight illuminates surfaces at roughly 100,000 lx (about 9,290 fc, or 10 phot). Overcast sky drops to 1,000–10,000 lx, sunrise and sunset to around 400 lx, deep twilight to 1–10 lx, and a clear full-moon night to about 0.1 lx. Daylight is therefore roughly 200 times brighter than a standard 500 lx office — which is why glare and contrast, not darkness, are the real daylight problems indoors. Photographers' sunny-16 rule, indoor/outdoor exposure differences, and lighting-code daylight harvest targets all trace back to these orders of magnitude.
What is a phot unit?
The phot (ph) is a legacy CGS unit of illuminance: one lumen per square centimeter. Since one square meter contains 10,000 square centimeters, 1 phot = 10,000 lx = 10 klx. It appears in older European and scientific literature — a museum conservation limit written as 0.005 ph means 50 lx, the same figure modern guidelines cite. The phot fell out of use because it sits at an awkward scale: everyday illuminance in phot is a fraction like 0.05, while lux keeps numbers in comfortable ranges. Enter a phot value in the converter to see it expressed in lux, klx, fc, and nox instantly.
What is a nox and when is it used?
The nox is a niche unit for extremely low illuminance: 1 nox = 0.001 lx (one millilux). It serves fields where lux numbers become tiny decimals — night-vision research, low-light sensor characterization, dark-sky measurement, and astronomy-adjacent scene descriptions. A moonlit night is about 0.1 lx, or 100 nox; starlight-only conditions are a few nox. Using nox keeps readings in whole numbers instead of expressions like 0.05 lx. It never appears in lighting codes because no human task happens at those levels — it exists purely for the science of seeing in the dark.
What is the difference between lux and lumens?
Lumens measure the total light a source emits in all directions; lux measures how much of it lands on each square meter of a surface. They connect through geometry: 1 lx = 1 lumen spread over 1 m². A 800-lumen bulb lighting a 20 m² room evenly delivers about 40 lx — dark — while the same bulb over a 2 m² desk area delivers 400 lx, near office standard. Lumens describe the source; lux describes the destination, and the ratio depends on distance, beam angle, and reflectance. This is why a bulb's lumen rating never tells you whether a room will be adequately lit without a layout calculation.

Related Tools