Flow rate is one of those numbers that arrives in whichever unit the equipment's country of origin prefers. A US shower head is rated in gallons per minute (GPM), its European counterpart in liters per minute; a pump datasheet says cubic meters per hour; an HVAC duct specification says cubic feet per minute (CFM); a laboratory protocol says liters per second. This converter bridges all five — L/s, L/min, m³/h, GPM (US), and CFM — in one step. Enter a value, pick its unit, and all five conversions refresh live as you type.
It runs entirely in your browser: free, no signup, nothing sent to any server. It works on a phone, which suits the setting — plumbing aisles, pump rooms, and mechanical rooms are where flow-rate questions actually get asked.
Five simultaneous results exist because flow comparisons always cross system boundaries. A 10 m³/h pump curve needs translating into GPM before it can be compared against an American fixture list; a 400 CFM exhaust fan needs m³/h before it faces a European ventilation code. One entry shows the whole picture, computed from exact factors.
What Units Does This Converter Handle?
- Liters per second (L/s). The SI-derived workhorse. Fire-hydrant flow tests, pump curves, laboratory peristaltic pumps, and hydrology calculations all use it.
- Liters per minute (L/min). The everyday European fixture unit: shower heads, taps, aquarium filters, medical oxygen flow.
- Cubic meters per hour (m³/h). The industrial and water-utility standard: pump duty points, water meter registers, irrigation systems.
- Gallons per minute, US (GPM). The American fixture and pump unit. US shower heads are capped at 2.1 GPM by federal rule; residential well pumps are commonly sized in GPM.
- Cubic feet per minute (CFM). The HVAC and compressed-air unit in North America: fan curves, duct sizing, air-changer calculations, air-compressor ratings.
The definitions behind them are exact: 1 US gallon is 3.785411784 liters, so 1 GPM is 3.785 L/min, which works out to 6.30902 × 10^-5 m³/s. One CFM is one cubic foot per minute; a cubic foot is 28.316846592 liters, giving 4.7194744 × 10^-4 m³/s, or 28.317 L/min. Note "GPM" here means the US gallon used in American plumbing — the imperial gallon of the UK and Commonwealth (4.54609 L) is a different, larger unit about 20% bigger, and equipment sold internationally can occasionally quote it.
How to Use This Converter (Step by Step)
- Type the flow value you have — 2.1, 10, 400, or any decimal.
- Select its unit: L/s, L/min, m³/h, GPM, or CFM.
- Read all five results, updated on every keystroke with no button to press.
- Change the value or unit for the next comparison.
Worked example one: enter 2.1 and choose GPM, the US legal maximum for a shower head. The results are 7.95 L/min, 0.1325 L/s, and 0.477 m³/h — over a ten-minute shower, about 79.5 liters of hot water. Worked example two: enter 10 and choose m³/h, a small pump duty point. The results are 2.7778 L/s, 166.67 L/min, and 44.0 GPM, plus 5.89 CFM of water flow.
How It Works: The Exact Conversion Factors
Everything anchors to SI through exact definitions:
1 GPM = 3.785411784 L/min = 0.22712 m³/h = 6.30902 × 10^-5 m³/s1 CFM = 28.316846592 L/min = 1.69901 m³/h = 4.7194744 × 10^-4 m³/s1 m³/h = 16.6667 L/min = 0.277778 L/s1 L/s = 60 L/min = 3.6 m³/h = 15.8503 GPM = 2.11888 CFM
Internally, the input is normalized to a base value in m³/s and the other four results derive from that single base, so the set stays mutually consistent. Two quick anchors to memorize: 1 GPM ≈ 3.79 L/min and 1 CFM ≈ 1.70 m³/h. Worked example: a well pump delivering 12 GPM supplies 12 × 3.785 = 45.4 L/min, which fills a 200-liter tank in about 4.4 minutes.
Reference Table: Common Flows in All Five Units
| Application | L/s | L/min | m³/h | GPM (US) | CFM |
|---|---|---|---|---|---|
| US-compliant shower head | 0.1325 | 7.95 | 0.477 | 2.1 | 0.2807 |
| Kitchen tap, full flow | 0.158 | 9.5 | 0.57 | 2.5 | 0.334 |
| Standard garden hose | 0.316 | 19 | 1.14 | 5.0 | 0.671 |
| Fire hydrant flow test | 31.5 | 1,893 | 113.6 | 500 | 66.84 |
| Residential HVAC blower | 188.8 | 11,327 | 679.6 | 2,992 | 400 |
Notice how the CFM row belongs to air while the others are water — that is exactly the cross-domain trap this table exposes. The same numeric value means very different things depending on whether it was written by a plumber, a pump engineer, or an HVAC designer.
Common Use Cases
- Shower and fixture compliance. US law caps shower heads at 2.1 GPM (7.95 L/min); faucets at 1.2–2.2 GPM depending on standard. European specs quote L/min. Converting confirms whether an imported fixture meets local code before purchase.
- Pump selection and curve reading. Pump curves are drawn in m³/h or GPM depending on origin. A pump whose best-efficiency point is 10 m³/h is a 44 GPM machine — a figure the seller may never state.
- HVAC and ventilation. Sizing rules like "roughly 400 CFM per ton of cooling" or "6–10 air changes per hour" are CFM-based, while European ventilation codes use L/s or m³/h. A 400 CFM fan is 680 m³/h — the number a European engineer needs to see.
- Irrigation and well systems. Well yield is tested in GPM in the US and m³/h elsewhere; sprinkler zones and drip emitters quote L/min. Matching supply to demand requires one common scale.
- Laboratory and medical settings. Peristaltic pumps quote mL/min or L/s, oxygen flow is L/min, and vacuum systems use CFM. Research protocols written in one country get executed with equipment bought in another.
Tips and Best Practices
- Confirm which gallon is meant. US and imperial gallons differ by 20%. Most modern documents mean US; British pump and fuel-consumption documents from older Commonwealth sources sometimes do not. When the numbers seem 20% off, this is why.
- Do not compare water CFM against air CFM expectations. A pump moving 10 CFM of water and a fan moving 400 CFM of air are both ordinary. Air is about 830 times less dense than water, so air flows are quoted in much larger numbers by convention.
- Convert once, at the boundary. If a design mixes units, translate everything into one system (SI is safest) at the start. Chaining back-and-forth conversions through round numbers accumulates real error — 10% sizing mistakes in plumbing are usually rounding histories, not physics.
- Respect the fixtures' pressure dependence. A "2.1 GPM shower head" rating applies at 80 psi. At lower pressure, flow drops. The conversion is exact; the fixture's behavior is not linear in life.
- Use the anchors. 1 GPM ≈ 3.79 L/min, 1 CFM ≈ 1.70 m³/h, 1 m³/h = 16.67 L/min. If a conversion misses these by a wide margin, the selected unit is wrong.
Limitations and Honest Caveats
This tool converts between units of volumetric flow rate — volume moved per unit time. It does not convert mass flow (kg/h, lb/min), which requires the fluid's density and differs between water, air, and fuel; it does not model pressure, head losses, pipe sizing, or velocity, all of which determine whether a given flow is achievable in your actual system. It uses the US gallon, not the imperial gallon, and standard CFM, not the corrected SCFM or ACFM conventions of compressed-air work, which adjust for temperature and pressure. For exact unit conversion among L/s, L/min, m³/h, GPM, and CFM, it is complete.
Why Flow Rate Refuses to Standardize
Volumetric flow inherits the unit chaos of volume itself, and each industry froze its convention before globalization forced comparison. Plumbing matured around gallons and liters, water utilities around cubic meters per hour, HVAC around cubic feet per minute — because early fans were rated by room volume in cubic feet. None of the five units is going away, so practical competence means instant translation rather than memorization. The two numbers worth carrying in your head are 1 GPM ≈ 3.79 L/min and 1 CFM ≈ 1.70 m³/h; everything else this converter computes for you — five units from one entry, exact factors throughout, updating live in your browser with nothing sent anywhere.